Product Overview
National Guard Products 9595 Door Bottom Gap Solution up to 90 Minutes
The 9595 Door Bottom is designed to accommodate up to 1 3/8″ excessive gap at the door bottom of fire-rated wood or steel door rated up to 90 minutes. The 9595 Door Bottom can be used with or without the thru-bolted door bracket. To accommodate metal doors or to install on wood doors without taking down the door, the door bracket must be used. If the door is taken down, the 9595 Door Bottom without door bracket can be used to limit the visibility of surface-applied hardware.
UL Certified Solution for Fire Doors With Excessive Clearance Between the Bottom of the Door and Finished Floor, up to 1-3/8″
- Application Certified on Both Hollow Metal and Wood Fire-Rated Doors – up to 90-Minutes
- Non-Handed
- L-bracket allows Installation while Door Remains on Hinges
- Can be Trimmed in the Field up to 1-1/2″ per Side, 3″ Total
- Designed to Travel Over Uneven Floors, with a Range of 3/8″
- Visibility of Hardware is Minimized by Using L-Bracket on Pull-Side of the Door
- May be Fastened to the Underside of the Door’s Bottom Rail to Minimize Visibility
- End Caps Set Height Position and Provide a Finished Look
- Product consists of: L-Bracket, 16-Gauge Steel, Embossed with UL Mark, Door Bottom Assembly, 18-Gauge Steel, End Caps, 18-Gauge Steel, Embossed with UL Mark
- Hardware Pack: #10 × 1-1/2″ PHPH SS SMS (DKB), #8-32 × 1-3/4″ PHPH SS Thru-Bolt (DKB), #6 × 3/8″ SS TEK, #10 × 2″ PHPH SS SMS, #6 × 3/4″ FHPH SS SMS (DKB)
- Sizes: 36″, 42″ and 48″
- Certified for use in US and Canada
- Patented: US Patent US 11,761,262 B2
- Finish: Powder Coated: Matte Black
CERTIFIED by UL to CAN/ULC-S104 and ANSI/UL10B, complies with NFPA 80 and NFPA 252 for application to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door bottom undercut/clearances, measuring up to 1-3/8
POSITIVE PRESSURE – CERTIFIED by UL to ANSI/10C, complies with IBC, NFPA 80 and NFPA 252 for applications to Hollow Metal and Wood fire doors rated up to 90 minute with excessive door bottom undercut/clearances, measuring up to 1-3/8
Brand | |
---|---|
Length | 36", 42", 48" |
Fire Rating | 90-Minute Rated — for Use on UL10B and UL10C Wood or Hollow Metal Fire Doors |
Finishes | Matte Black, Powder Coated |
Related Products
-
NGP (National Guard) - HP90-ME Meeting Edge Excessive Gap Solution for Edge of Fire Doors
Starting at: $342.79 -
NGP (National Guard) - HP90-CYL Cylindrical Hardware Prep Filler, Fire Door Repair Kit
$161.23 -
NGP (National Guard) - GAPGUARD HP-90 Hardware Prep Fillers for Fire Doors, 10 Pack
Starting at: $66.63 -
NGP (National Guard) - GAPGUARD Fire Caulk for Fire Door and Frame Repair, Case of 10 Cartridges
$295.82 -
NGP (National Guard) - 9990 Fire Door Top Gap Solution for Excessive Clearance
Starting at: $265.83 -
NGP (National Guard) - 9590 Fire Door Bottom Excessive Gap Solution, Door Sweep and Shoe
Starting at: $293.82 -
NGP (National Guard) - GAP90 Perimeter Gap Solution for Excessive Fire Door and Frame Clearances
Multiple FinishesStarting at: $146.91 -
Pemko - 325XGSSN Door Bottom Sweep, Fire Door Excessive Gap Solution
Multiple FinishesStarting at: $329.99