NGP (National Guard) GAP90 Perimeter Gap Solution for Excessive Fire Door and Frame Clearances

Usually Ships: 3-5 Business Days
  • Applied to the door frame (head and/or jambs)
  • UL Certified for gaps measuring over 1/8″, and up to 5/16″
  • Helps bring fire doors back into compliance

Available Options:

NGP Gap90 – Fire Door Head / Jamb Gap Solutions — Up To 90 Minutes

NGP’S UL CERTIFIED 90-MINUTE FIRE DOOR GAP SOLUTIONS WILL HELP YOU AVOID THE COST, LABOR, AND DISRUPTION OF REPLACING EXISTING STRUCTURES TO ACHIEVE COMPLIANCE.

  • UL Certified Solution for Fire doors with Excessive clearance between door and frame over 1/8″, up to 5/16″
  • POSITIVE PRESSURE – CERTIFIED by UL to ANSI/UL10C, Complies with IBC, NFPA 80 and NFPA 252 for Application to Hollow Metal and Wood Fire Doors Rated up to 90 Minute with Excessive Door and Frame Clearances, Measuring up to 5/16″
  • Restricts the Passage of Smoke
  • Non-Handed
  • Requires installation of ALL components 9945, 9400, 5075
  • Certified for use on doors with Rim Exit Devices, refer to Installation Instructions
  • Doors with Parallel arm closers – use 9990
  • An NGP Strike Shim (9275 or 9225) may also be Required for Proper Latchbolt Engagement
  • Available in 36″, 48″, 84″ and 96″ lengths (order 1 piece for head and 2 pieces for jambs)

Steel Stop Extender – 9945

  • 16-Gauge, Gray Primer Finish
  • Furnished with #10 X 1″ TEK SMS
  • Patent No.: US9,273,510B2
  • Embossed with UL Mark

Self-Adhesive TPE Seal – 5075

  • 5075B BROWN (with DKB)
  • 5075CL CLEAR (with GRAY)

NGP-Edge® Intumescent Seal with PVC Cover – 9400

  • 9400 GRAY (with GRAY)
  • 9400DKB BROWN (with DKB)

GAP90™
Requires Installation of ALL Components:
9945, 9400, 5075CL

GAP90DKB™
Requires Installation of ALL Components:
9945, 9400DKB, 5075B

Brand

Finish

Dark Brown, Gray

Size

36", 48", 84", 96"

Fire Rating

90 minute rated UL Certified Miscellaneous Fire Door Accessory UL10B and UL10C wood or hollow metal fire doors

Related Products

  • 9945EC

    NGP (National Guard) - 9945EC End Cap For Use on GAP90 Steel Stop Extender Component 9945, 10 Pack

    $43.31
  • NGP_GAP90-ME

    NGP (National Guard) - HP90-ME Meeting Edge Excessive Gap Solution for Edge of Fire Doors

    Starting at: $342.79
  • NGP-HP90-GapGuard-Hardware-Prep-Fillers

    NGP (National Guard) - GAPGUARD HP-90 Hardware Prep Fillers for Fire Doors, 10 Pack

    Starting at: $66.63
  • NGP_GAP_9990

    NGP (National Guard) - 9990 Fire Door Top Gap Solution for Excessive Clearance

    Starting at: $265.83
  • NGP_GAP_9590

    NGP (National Guard) - 9590 Fire Door Bottom Excessive Gap Solution, Door Sweep and Shoe

    Starting at: $293.82
  • PEMKO_325XGSSN

    Pemko - 325XGSSN Door Bottom Sweep, Fire Door Excessive Gap Solution

    Multiple Finishes
    Starting at: $329.99
  • PEMKO_XG2212APK773

    Pemko - XG2212_PK773 Door Bottom Shoe, Fire Door Excessive Gap Solution

    Multiple Finishes
    Starting at: $329.99
  • pemko-hss2000-intumescent-hot-smoke-seal-edge-sealing

    Pemko - HSS2000 Hot Smoke Seal Intumescent Edge Sealing

    Starting at: $24.64
NGP (National Guard) GAP90 Perimeter Gap Solution for Excessive Fire Door and Frame Clearances